POST INSTALLATION CHECKOUT
Once the unit is installed, complete the checkout procedure to verify proper operation. Refer
to the User’s Guide for operating instructions.
The steps that are not applicable to a particular installation may be skipped. A checkout log
sheet is included on page 27 to fill out during the checkout procedure. Make a photocopy of
the log sheet for ease of use if desired.
The checkout procedure is broken into several groups. The GPS Navigation Checkout, VHF
Comm Checkout (SL60), and the Final System Check should be completed with the aircraft
moved clear of hangers and other structures.
Mounting / Wiring Check
Verify that all cables are properly secured and shields are connected to the rear of the
mounting frame. Check the movement of the aircraft controls to verify that there is no
interference.
TEST MODE CHECKOUT AND SETUP
The SL50/60 has a built-in test mode to simplify the checkout. To operate the SL50 in the test
mode, hold down the WPT and MSG buttons while switching on the power. For the SL60, hold
down the COM and MSG buttons. To return to normal operation, switch the power off, then
back on.
Avionics Outputs
Check the avionics output connections by using the test mode as follows. Rotate the LARGE
knob to select each test.
1. Using the “CDI TRIANGLE” page, rotate the SMALL knob to check left, mid, and right.
2. Using the “TO/FROM FLAG” page, rotate the SMALL knob to check the Off, To, and From
outputs.
3. Using the “LAMP OUTPUTS” page, rotate the SMALL knob to check all the connected
annunciators.
4. Using the “V
ALID FLAG PAGES” page, rotate the SMALL knob to check all the connected
valid flag outputs.
Installation Configuration
The SL50/60 must be configured to match the operation supported by the installation. This
includes IFR and VFR operation selections.
1. In test mode, rotate the
LARGE knob to the “OPTIONS:” page.
2. Press SEL, rotate the SMALL knob to select VFR (IFR? NO) or IFR (IFR? YES) operation,
then press
ENT when complete.
Note: Make sure that all installation requirements are complete for the selected operation.
Refer to the System Configurations section on page 4 for installation requirements.
Serial Interface Configuration
The SL50/60 RS-232 serial port can be configured for several different input and output
formats. To select the serial port configurations:
1. In test mode, rotate the
LARGE knob to the serial port configuration “SERIAL PORT” page.